Humidification:
The transfer of material between a pure liquid phase and a fixed gas that is insoluble in the liquid is dealt with as humidification. The adiabatic saturation temperature is attained by the gas. The dry bulb temperature of a gas is more than the wet bulb temperature. Relative humidity is the ratio of the partial pressure of the vapor to the vapor pressure of the liquid at the gas temperature.
At all humidities other than 0 and 100 percent, the percentage humidity is less than the relative humidity. Heat in BTU necessary to increase the temperature of 1 lb of gas and its accompanying vapor by 1oF is called humid heat. The cooling tower is an example of a humidification operation. In a cooling tower, water is cooled from 95 oF to 80 oF by exposure to air with a wet-bulb temperature of 70 oF.
The heat required to vaporize 1 lb of water is roughly 1000 BTU. The lowest temperature to which water can be cooled in a cooling tower throughout the year depends on the maximum wet bulb temperature. The adiabatic saturation line and wet bulb temperature line are the same for the system air–water. If a warm vapor-gas mixture is contacted with cold liquid so that the humidity of the gas is sensible heat transfer will occur from the gas to the liquid. The purge of a small amount of water from a cooling tower is necessary in order to keep the load on the cooling tower at a specified level and keep the dissolved salt concentration at a specified level. The dewpoint of a gas-vapor mixture (for a fixed vapor mole – fraction in gas) increases with an increase in pressure.
During the evaporative cooling process with recirculated water, the wet bulb temperature remains constant while the partial pressure of vapor and relative humidity increases. When a gas-vapor mixture is cooled by sensible heat transfer relative humidity decreases & wet bulb temperature decreases. If PA is the partial pressure of vapor A in a vapor-gas mixture and PS is the saturation vapor pressure of liquid A, condensation of the vapor-gas mixture just begins when P A = PS. During adiabatic saturation of unsaturated air, the parameter that remains substantially constant is wet bulb temperature. For example, if an unsaturated air-water vapor mixture at a dry bulb temperature of 40oC. The dew point for the mixture is 20 C. The mixture is passed through a water spray chamber maintained at 17oC. The air, on passage through the chamber, will be cooled and dehumidified with a decrease in wet bulb temperature.
Related Search – Click Here
- MASS TRANSFER DRYING
- What Is Diffusivity And How It Is Related To Mass Transfer And Its Coefficient, How They Are Related?
- Level Measuring Methods | MAGNESIUM AND ALKALINITY
- Hydrorefining Of Crude Benzol Flow Sheet
- Mass Transfer Operation Humidification
- HEAT TRANSFER In Boiling Condition
- HOLD– UP STUDIES (FLOODING VELOCITY)
- Calculation Of Steam Consumption And Vaporization Capacity Using OPEN PAN EVAPORATOR
- What Is Glass And What Types Of Glasses